FUNCTIONAL PRINCIPLE The nitrate remover ensures consistently high water quality and removes nitrate from the water. No chemicals, additives or additional technical equipment are required, just commercially available regeneration salt. The entire system is automatically cleaned during each regeneration. In the ion exchange process, water flows through the ion exchange resin, which has a high nitrate selectivity. Nitrate ions are exchanged for chloride ions. When the capacity of the system is exhausted, the ion exchange resin is regenerated with brine, and the nitrate ions are discharged into the wastewater. DIMENSIONS NEAK–20 M • A 730 • B 980 • C 1070 • D 1110 • E 320 • F 520 All values (mm) TECHNICAL DATA NEAK–20 M • Resin quantity (litres) 20 • Capacity (m3 x NO3) 360 • Salt per regeneration (kg) 2.6 • Max. Salt supply (kg) 75 • Max. flow rate (m3/h) 2.0 • Min./Max. Operating pressure (bar) 2/6 • Minimum/maximum water temperature (°C) 5/30 • Electrical connection (Volt/Hz) 230/50 • Length of power connection cable (m) 4.5 • Water connection (inch) 1 • Overflow angle connection (inch) 1/2 • Waste water connection (inch) 1/2 Note: The water to be treated must be free of impurities, iron and manganese (less than 0.1 mg/l in each case). A B C D E F 75
RkJQdWJsaXNoZXIy MTkyODMyNw==